Product Details:
|
Name: | Elevator Bistable Switch | Voltage: | 250V AC/DC |
---|---|---|---|
Dielectric Strength: | 800 VDC | Switching Capacity: | 120W/VA |
Switching Current: | 3 A | Model: | Elevator Bistable Switch |
Type: | Elevator Bistable Switch | ||
Highlight: | lift components,elevator accessories |
120W / VA 250V AC / DC Elevator Bistable Switch Door Bi - Stable Switch
P/N:SN-KCB_R-III(LED) Door Bi-Stable Switch
Testing method:
1.When the magnet moved to the upward of the switch, the switch would be closed with LED indicator lighted, and kept this situation even the magnet left.
2.When the magnet moved to the switch in the opposit direction, the switch would be open with LED indicator went off.
Note:This switch had successfully won national patent for protection.
Switching capacity | Max | 120W/VA | Switching time without bounce | Max | 3.5ms |
Switching voltage | Max | 250V AC/DC | Bounch time | Max | 0.5ms |
Switching current | Max | 3 A | Release time | Max | 0.2ms |
Carrying current | Max | 5 A | Resonant frequency | typ | 900Hz |
Dielectric strength | Min | 800 VDC | Operating frequency | Max | 100Hz |
Insulation resistance M | Min | 10* Ohms | Shock 11ms | Max | 50g |
Operating principle | Magnet | Magnetic | Testing distance | mm | 5~15 |
Product choice | SN-KCB_R-IIIB(LED) |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.