Product Details:
|
Name: | Integrated Controller | Power(kW): | 5.5~37 |
---|---|---|---|
Type: | Elevator Parts | Applicable: | Elevator Equipment,Passager Elevator |
Output Voltage (V): | 3-phase 380V AC | Packing: | Standard Packing |
Transportation: | DHL TNT FEDEX | Applicable Elevator: | Elevator Parts |
Model: | Integrated Controller | Product: | Integrated Controller |
High Light: | AS380S Elevator Electrical Parts,Integrated Controller Elevator Electrical Parts,Vector Control Elevator Electrical Parts |
Main Features
Galvanizing case, painting cover, acrylic window
Advanced modular design, connection with plugs, more reliable
Aluminum extrusion radiator, more efficient heat release
Connectors with 5.08mm pitch, easier wiring
Balance coefficient self-learning
Comply with EN81-20
Specification Data
Model AS380 | Rated capacity (kVA) | Rated output current (A) |
Rated power of motor (kW) |
4T05P5S | 8.5 | 13 | 5.5 |
4T07P5S | 14 | 18 | 7.5 |
4T0011S | 18 | 27 | 11 |
4T0015S | 24 | 34 | 15 |
4T18P5S | 29 | 41 | 18.5 |
4T0022S | 34 | 48 | 22 |
4T0030S | 50 | 65 | 30 |
4T0037S | 61 | 80 | 37 |
Technical Indicators
Item | Indicators | |
Maximum output voltage | Input voltage | |
Input power supply | Number of phases, voltage, and frequency | Three phase, 380V, 50/60Hz |
Voltage range | -15%-+10% | |
Frequency range | -5%~+5% | |
Instantaneous voltage drop | Input voltage < AC300V, low-voltage protection after 15 |
|
Basic features | Floor number | 2-64 |
Elevator rated speed | ≤2.50m/s | |
Group control units | ≤8 units | |
Communication mode | CAN-Bus | |
Control features | Control mode | Close loop vector control |
Overload capacity | Zero speed, 150%;< 3Hz,160%; > 3Hz, 200% | |
Braking torque | 150% (External brake resistor), built-in brake unit | |
Protection grade | IP20 | |
Installation mode | Installed in the cabinet |
Installation Information
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.
Contact Person: Brenda
Tel: +8613795300769