Product Details:
|
Name: | Wire Rope | Speed: | ≤5m/s |
---|---|---|---|
Used: | Elevator Parts | Size: | Na |
Applicable: | Passenger Lift | Warranty: | 1 Year |
Warranty Time: | 12 Months | Packing: | Standard Export Package |
Model: | Lift Wire Rope | Type: | Lift Wire Rope |
High Light: | Passenger Elevator Wire Rope 5m/S,5m/s Lift Elevator Wire Rope,ISO9001 Elevator Wire Rope |
Standard Elevator Steel Wires, Galvanized Steel Wire Rope For Passenger Elevator
For the various designs of elevators, The rope is subject to very different stresses. The design and choice of the suitable construction is done
by optimizing between:
A. High Bending Resistance
B. High Resistance to Abrasion
C. Low Elongation
Types of rope drives
1 cabin
2 counter weight
3 traction sheave(drum)
4 rope pulley
5 idle pulley
Sheave Grooves
Traction sheaves are made from cast iron. Both non-hardened as well as hardened pulleys are in service
Depending on the required friction, different groove shapes are used within the driving pulley. Sometimes, the rope is guided well
(round groove) or pressed into the groove (V-groove), thus creating enormous transversal pressures on the rope cross section
Type Of Rope |
T/S of Outside wire | Brinell | Vickers | Recommended hardness grade for traction sheaves (Brinell) |
Testing Values |
8×19S-NFC | 1370 | 400 | 430 | 200~230 | 420-460 |
8×19S-CSC | 1570 | 460 | 480 | 220~250 | 460-500 |
8×19S-CSC 8×19S-IWRC |
1570 | 460 | 480 | 220~250 |
460-470 478-480 |
6×19S-FC | 1770 | 510 | 530 | 260~290 | 520-530 |
6×19S-SFC | 1370/1960 | 400/560 | 420/590 | ||
8×19S-SFC | 1370 | 400 | 420 |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.
Contact Person: Mr. Wei CHEN
Tel: +86-13661864321
Fax: 86-021-59168286