Product Details:
|
Product Name: | Light Curtain For Elevator Door | Thickness: | 25 Mm |
---|---|---|---|
No. Of Diodes: | 64 | Specialty: | 8-channel Special Design |
Type: | 2 In 1 | Quality Assurance: | 2 Years |
Highlight: | lift light curtain,elevator door detector,25mm thick elevator light curtain |
25mm Thickness Light Curtain for Elevator Door, SN-GM1-A25192H
1. Patent Product channel function
2. Elevator light curtain H series 9mm
3. Real 64 diodes192 beams
4. More safety based on the 2 in 1 design
5. CE UL CCC certificate
SUNNY elevator light curtain H series has obtained national invention patent (No. ZL01105213.9), which is widely used in luxury elevator and is famous for its 8-channel special design, which means any one can make urgent repair by pushing the blinking switch on the control box to avoid great inconvenience to the elevator users when some diode is broken.
SUNNY light curtain, with 64 pairs of diode inside, 192 beams and 10 ms quick response time, is much safer and much more reliable than the product in the market, which ensure the safest protection area even the door is nearly closed ( door width is under 300mm).
Specification |
Model |
|
192H |
320HG |
|
No. of diodes |
64 |
64 |
Max. beams |
192 |
320 |
Min. beams |
192 |
192 |
Distance between Two Diodes |
emitter/ receiver 42/ 55 mm |
|
Size |
1980 height x 30 width x 9/16/35 thickness mm |
|
Light curtain Detecting Distance |
0~4.5 meters Customized to reach 20 meter |
|
Light-proof |
can work under the sunlight ≥100,000 lux |
|
Installation Tolerance |
Vertical ≤± 20mm, horizontal ≤ ± 10mm, angle ≤ ±7° |
|
Working Temperature |
-25℃~+65℃ |
|
IP |
Ip33 circuit strip Ip63 controller box |
|
Response Time |
≤80 ms |
|
Cable Strength |
3C, 4.5M*2, 1 million times of life |
|
EMC |
En61000 GB/T17626 |
|
Timeout Response |
25±5s Buzzer rouse |
|
Power |
≤ 7.5 VA |
|
Voltage Range |
85~264VAC 60/50Hz |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.
Contact Person: Mr. Wei CHEN
Tel: +86-13661864321
Fax: 86-021-59168286